33Installation instructions geoTHERM VWS/VWW 0020057444_01
6.7.3 Mixer circuit with buffer cylinder
(Hydraulic plan 2)
The unregulated underfloor heating circuits are operat-
ed by the external heating circuit pump from the buffer
cylinder via a mixer. The flow temperature sensor sits
behind the external pump.
The heat pump responds to a demand for heat from the
buffer cylinder.
VF1
46
VF2
27
RF1
42b
42a
32
33
30
31
30
31
M
400 V
400 V
AF
WQ
16
Fig. 6.9 Hydraulic plan 2
Key to Fig. 6.9
16 External sensor (AF)
27 CH pump
30 Non-return valve
31 Control valve with position indication
32 Cap valve
33 Air separator/Dirt filter
42a Expansion relief valve
42b Expansion vessel
46 3-way mixer valve
VF1 Buffer cylinder head temperature sensor
VF2 Supply temperature sensor
RF1 Buffer cylinder base temperature sensor
WQ Heat source circuit
Electrical installation 6