Operating instructions ecoTEC plus 0020124810_FT1b
4.8 Switching the heating system off
4.8.1 Switching hot water production off (VU unit)
You can switch off cylinder charging without switching
off heating mode.
> Set the lowest possible hot water temperature by
pressing the following sequence of keys:
"Operating mode" selection button
--> "Next"
The hot water temperature is shown on the display.
> Change the hot water temperature to the lowest value
30 °C with the "Scroll down"
arrow key.
> Confirm the change by pressing the "OK" selection
button
.
Cylinder charging is switched off. Only the frost
protection function for the cylinder remains active.
4.8.2 Switching heating mode off ( summer mode)
Target flow temp.
1/4
Cancel Ok
Heating off
Fig. 4.11 Switching off heating mode (summer operation)
You can switch off the heating mode in summer without
switching off the hot water supply.
> Set the heating flow temperature to "Heating off"
with the "Scroll down"
arrow key.
> Confirm the change by pressing the "OK" selection
button
.
Heating mode is switched off.
4.8.3 Temporarily taking the boiler out of service
b
Caution!
Material damage caused by frost!
Frost protection and monitoring devices are
only active while the boiler is connected up to
the power mains and the on/off switch is on.
> Do not isolate the boiler from the power
mains.
> Leave your boiler switched on at the on/off
switch.
> Only switch the boiler on and off in normal
mode using the controller.
> Make sure that the boiler cannot become
damaged by frost.
1
2
Fig. 4.12 Switching off the boiler
> Press the on/off switch (1) to switch off the boiler.
If the boiler is switched off, the display (2) turns off.
i
If the boiler is going to be unused for longer
periods (e.g. holiday), you should also close
the gas stop cock and the cold water stop
valve, but only if there is no risk of frost.
i
The isolator devices are not included in the
scope of supply of your boiler. These are
installed are fitted by your heating engineer
on site.
> Ask your heating engineer to explain to you the
position and handling of these isolator devices.