Glossary
68 ecoTEC plus installation and maintenance instructions 0020134823_01
19
19 Glossary
Burner anti-cycling time
The burner is electronically locked for a specific time after
each time it is switched off ("restart interlock") to avoid fre-
quent switching on and off of the burner (energy losses)
and to extend the working life of the boiler. The burner anti-
cycling time is only activated for the heating mode. Hot
water handling is not affected if burner anti-cycling time is
running.
Calorific value
Unlike the heating value, the calorific value of a fuel
describes the total useable heat during combustion, based
on the quantity of fuel used, including the condensation
heat in the steam.
The energy contained in steam can also be used if the
steam liquefies on cooling.
Condensing technology
Technology which uses the calorific value of the fuel that is
used. To do this, the flue gases are cooled below the dew
point of the flue gas so that the steam they contain con-
denses. The condensation heat that this releases can also
be used.
In particular, the flue gas losses are greatly reduced. The
losses from conduction of heat and radiation are also
reduced by the lower system temperatures. The entire heat-
ing installation should therefore be designed for low system
temperatures (flow/return temperature) for the effective
use of the calorific value. The level of efficiency attainable
for boilers is always given based on the heating value of the
gas. Due to the additional condensation heat used, the cal-
culated values can exceed 100 %.
Dew point
The dew point is the temperature at which steam turns to
liquid (condensation). The steam in the flue gas from the
boiler contains thermal energy, which can be released by
condensation. In gas-fired and oil-fired boilers using calo-
rific values, the flue gases are cooled so that the steam
condenses and the heat that it contains can be output into
the heating system.
Digital information and analysis system (DIA)
The Vaillant ecoTEC plus boiler is fitted with a digital infor-
mation and analysis system (DIA). If additional settings are
required, which have not been configured using the installa-
tion assistant, you can view and modify further parameters
using the DIA.
eBUS
eBUS is an abbreviation for energyBUS. The eBUS is a spe-
cial bus used in heating technology, which assists the com-
munication between intelligent components in the heating
technology. In a Vaillant system, up to eight different heat
generators can be connected via the eBUS. The eBUS com-
munications protocol simplifies the control-related linking
of different system components within a heating installa-
tion. It provides particular flexibility for retro-fitting and
expanding the system. This simplifies the installation of
boiler cascades or the subsequent addition of components
such as solar hot water generation. The eBUS provides
extended possibilities for connecting controllers and also
for connecting to the vrnetDIALOG Internet communica-
tions system for remote servicing and diagnosis.
Flue pipe
A flue pipe is a line system with two separate flow channels.
The flue gas is routed into separate chambers at the same
time as the required combustion air is pumped to the boiler.
The flue pipe can be designed as a concentric or adjacent
double flue gas pipe (the flue gas channel is sealed from
the air channel). Floor-standing boilers and gas-fired wall-
hung boilers can be operated as room-sealed through the
flue pipe. As a result, boilers can be installed in new build-
ings that, due to their airtight construction, do not offer
sufficient combustion air for open-flued heat generators.
Gas-air mixture unit
The gas-air mixture unit is an assembly in Vaillant condens-
ing units, which consists of the following four main compo-
nents in the ecoTEC plus: Speed-regulated fan, gas valve,
gas supply (mixture pipe) to the premix burner and premix
burner
Multi-functional module
The multi-functional module is an accessory that controls
additional functions or components in combination with
Vaillant boilers with eBUS electronics. It also allows you to
select and control 2 in 7 functions, e.g. circulation pump,
external heating pump, external solenoid valve or response
from the flue non-return flap.
vrnetDIALOG Internet communication system
Using the vrnetDIALOG Internet communication system for
remote setting and monitoring, you can set the heating
installation at the customer's home from your home PC.
Sono journey is required.
vrnetDIALOG can also forward fault messages by fax, E-mail
or SMS to you and thereby help with diagnostics. You can
therefore prepare your work in advance and, if required,
arrive at the customer's home with the right spare parts for
maintenance or repair.