Vaillant VCW-sine 18 T3 W Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Interrupteurs d'éclairage Vaillant VCW-sine 18 T3 W. TOWERCHRON QM1 and QM2 Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - TOWERCHRON QM1 and QM2

Installation and user instructionsENTOWERCHRON QM1 and QM22ONOFF

Page 2 - Table of Contents

10It is important that you always refer to the Boiler Manufacturers Instructions concerning electrical wiring before using the information contained i

Page 3 - Safety Instructions

EN11Boiler Terminal NumbersSaunier Duval SD 625M see special circuitVaillant VCW 20/1 T3W 1MP 2R 3 4Vaillant VCW 25/1 T3W 1MP 2R 3 4Vaillant VCW Sine

Page 4 - What is a programmer?

12Always use special 24V thermostat supplied with this boiler, and wire as indicated in boiler instructions substituting time switch terminals A and B

Page 5 - Specications

EN13“TOWERCHRON QM2”Applications (QM2)• Fully pumped central heating systems using mid position valves, spring return valves or “power open”, “power

Page 6 - “TOWERCHRON QM1”

14Setting time of dayRotate the minute hand of the clock until the arrowhead in clock face aligns with the correct time on the outer dial, i�e� 8 = 8�

Page 7

EN15Internal wiring diagram (QM2)N LHWOFFCHOFFHWONCHON1 2 3 4220/240V AC 50 Hz fused 3A• Carry out wiring installation using appropriate diagram as s

Page 8 - Internal wiring diagram (QM1)

16Wiring installation instruction (QM2)Gravity Hot Water / Pumped Heating - System with Room Stat to Control PumpThe following wiring diagrams are sch

Page 9

EN17Gravity Hot Water / Pumped Heating System - Two Port Valve in D�H�W� with Room and Cylinder StatsNote: Only valves with “change over“ end switches

Page 10 - Important note:

18Fully Pumped System using 2 Port Spring ReturnFully Pumped System using 3 Port Mid-Position ValveTOWERCHRON QM2EARTH NEUTRAL LINEHEATING VALVEHOT W

Page 11

EN19Conversion Chart for different Room / Cylinder ThermostatsCylinder Stats Room StatsE COMDEMSATTOWER CS1REDBLKYELACL HTS 2DRAYTON CS1 E 1 2 3HONEYW

Page 12 - Saunier Duval SD625M

2Safety Instructions �������������������������������������������������������������3What is a programmer? ���������������������������������������������

Page 13 - “TOWERCHRON QM2”

Grässlin GmbHBundesstraße 36D-78112 St� GeorgenGermanyPhone: +49 (0) 7724 / 933-0Fax: +49 (0) 7724 / 933-240www�graesslin�deinfo@graesslin�de80�10�079

Page 14 - Setting ON/OFF times

EN3Safety Instructions• Installation must be carried out by a qualied electrician and conformed to current IEE Regulations!• Mains supply must be s

Page 15 - Internal wiring diagram (QM2)

4What is a programmer?Programmers allow you to set ’On’ and ’Off’ time periods� Some models switch the central heating and domestic hot water on and o

Page 16

GBEN5SpecicationsInstallation double insulatedRating 5 amps (2 amps) at 240 volts 50 hertzFitting surface mounted or to a single gang plaster depth s

Page 17 - Cylinder Stats

6“TOWERCHRON QM1”Applications (QM1)• Any simple time switching application up to the stated rating�• Domestic heating system where both heating and

Page 18 - Mid-Position Valve

EN7Programming your “TOWERCHRON QM1”Setting time of dayRotate the minute hand of the clock until the arrowhead in clock face aligns with the correct t

Page 19

8Internal wiring diagram (QM1)N=~LOFF ON1 2 3 4• Carry out wiring installation using appropriate diagram as shown�• When the TOWERCHRON QM1 timeswit

Page 20 - Grässlin GmbH

EN9Simple circuit for for domestic central heating boiler with gravity fed hot water supplyThis diagram is correct for mains operated systems� The lin